WHP030HW.3N-R4
Solaraven
84186190
R410A fixed speed commercial air to water heat pump is designed for hot water heating for the villas, hotels, hospital and schools, where need big capacity of hot water daily. It's max water heating temperature is 55℃,hot water output is from 258liter/ hour to 4429liter/hour. Heating capacity from 12KW to 206KW.
There are 3 types of central hot water heating euqipment: electric or gas boiler, solar water heating system and commercial heat pump. The commercial heat pump has many advantages than others.
In terms of market penetration, Nordic countries are at the global leading level: Norway, for example, about 60% of households are equipped with heat pumps, and more than 40% of households in Sweden use heat pumps for heating. Thanks to the guidance of policies after the oil crisis in the 1970s, heat pump technology was popularised in Northern Europe early.
In contrast, only about 14~16% of households in the United States currently use heat pumps as the main heating mode. Heat pumps are more common in newly built houses in the southern United States (38% of new detached houses in 2021 use heat pump heating), but the whole country the overall penetration rate is still low.
Although China is one of the largest heat pump markets in the world, the penetration rate in building heating is still low: at present, China's decentralised heat pumps have met about 4% of the building heating demand. In 2022, heat pumps in China accounted for only 8% of the sales of heating equipment, and there is still huge room for growth.
Commercial heat pump Features:
R410A refrigerant, enviromental friendly
Higher water temperature output up to 55℃
Adopt EVI technology, the operation ambient temperature can reach at -25℃
High pressure protection
Defrost automatically
With MODBUS communication
Adapt intelligent controller, full automactically operation
Through different installation, the system can be used for cooling or heating
Commercial air to water heat pump system principle

Commercial air to water heat pump specification
| Model | WHP030HW-R4 | WHP030HW.3N-R4 | WHP050HW.3N-R4 | WHP100HW.3N-R4 | WHP150HW.3N-R4 | WHP200HW.3N-R4 | WHP250HW.3N-R4 | WHP300HW.3N-R4 |
| Heating performance condition: A20/15℃, W15~55℃ | ||||||||
| Heating capacity(KW) | 12 | 12 | 19 | 38 | 52 | 70 | 86 | 103 |
| Rated input power(KW) | 2.8 | 2.8 | 4.5 | 8.8 | 12.5 | 17 | 22.6 | 35.2 |
| COP | 4.29 | 4.29 | 4.22 | 4.32 | 4.16 | 4.12 | 3.81 | 2.93 |
| Hot water capacity(L/H) | 258 | 258 | 408 | 817 | 1100 | 1500 | 1850 | 2215 |
| Power supply | 220V/50HZ | 380V/50HZ | ||||||
| Waterproof grade | IPX4 | |||||||
| Max water heating temperature | 55℃ | |||||||
| Operating ambient temp. | -10℃~45℃ | |||||||
| Compressor | EMERSON Copeland Scroll | |||||||
| Inlet/outlet pipe size | DN25 | DN25 | DN25 | DN40 | DN40 | DN50 | DN50 | DN65 |
| Dimension(mm) | 680*680*870 | 680*680*870 | 770*770*780 | 1500*753*1080 | 1510*810*1530 | 1850*1000*2000 | 2000*1000*1850 | 2200*1100*2210 |
| Weight(KG) | 108 | 110 | 140 | 340 | 400 | 680 | 860 | 930 |
R410A fixed speed commercial air to water heat pump is designed for hot water heating for the villas, hotels, hospital and schools, where need big capacity of hot water daily. It's max water heating temperature is 55℃,hot water output is from 258liter/ hour to 4429liter/hour. Heating capacity from 12KW to 206KW.
There are 3 types of central hot water heating euqipment: electric or gas boiler, solar water heating system and commercial heat pump. The commercial heat pump has many advantages than others.
In terms of market penetration, Nordic countries are at the global leading level: Norway, for example, about 60% of households are equipped with heat pumps, and more than 40% of households in Sweden use heat pumps for heating. Thanks to the guidance of policies after the oil crisis in the 1970s, heat pump technology was popularised in Northern Europe early.
In contrast, only about 14~16% of households in the United States currently use heat pumps as the main heating mode. Heat pumps are more common in newly built houses in the southern United States (38% of new detached houses in 2021 use heat pump heating), but the whole country the overall penetration rate is still low.
Although China is one of the largest heat pump markets in the world, the penetration rate in building heating is still low: at present, China's decentralised heat pumps have met about 4% of the building heating demand. In 2022, heat pumps in China accounted for only 8% of the sales of heating equipment, and there is still huge room for growth.
Commercial heat pump Features:
R410A refrigerant, enviromental friendly
Higher water temperature output up to 55℃
Adopt EVI technology, the operation ambient temperature can reach at -25℃
High pressure protection
Defrost automatically
With MODBUS communication
Adapt intelligent controller, full automactically operation
Through different installation, the system can be used for cooling or heating
Commercial air to water heat pump system principle

Commercial air to water heat pump specification
| Model | WHP030HW-R4 | WHP030HW.3N-R4 | WHP050HW.3N-R4 | WHP100HW.3N-R4 | WHP150HW.3N-R4 | WHP200HW.3N-R4 | WHP250HW.3N-R4 | WHP300HW.3N-R4 |
| Heating performance condition: A20/15℃, W15~55℃ | ||||||||
| Heating capacity(KW) | 12 | 12 | 19 | 38 | 52 | 70 | 86 | 103 |
| Rated input power(KW) | 2.8 | 2.8 | 4.5 | 8.8 | 12.5 | 17 | 22.6 | 35.2 |
| COP | 4.29 | 4.29 | 4.22 | 4.32 | 4.16 | 4.12 | 3.81 | 2.93 |
| Hot water capacity(L/H) | 258 | 258 | 408 | 817 | 1100 | 1500 | 1850 | 2215 |
| Power supply | 220V/50HZ | 380V/50HZ | ||||||
| Waterproof grade | IPX4 | |||||||
| Max water heating temperature | 55℃ | |||||||
| Operating ambient temp. | -10℃~45℃ | |||||||
| Compressor | EMERSON Copeland Scroll | |||||||
| Inlet/outlet pipe size | DN25 | DN25 | DN25 | DN40 | DN40 | DN50 | DN50 | DN65 |
| Dimension(mm) | 680*680*870 | 680*680*870 | 770*770*780 | 1500*753*1080 | 1510*810*1530 | 1850*1000*2000 | 2000*1000*1850 | 2200*1100*2210 |
| Weight(KG) | 108 | 110 | 140 | 340 | 400 | 680 | 860 | 930 |