| Availability: | |
|---|---|
| Quantity: | |
KFXRS-7.0I
Solaraven
84186190
The split heat pump architecture delivers exceptional spatial and operational advantages for modern residential developments and commercial lodging. By structurally separating the system components, the active heat pump unit can be strategically installed on exterior walls, open balconies, or other well-ventilated outdoor environments. Meanwhile, the heavily insulated water tank tucks neatly into tight indoor corners of bathrooms, utility closets, or kitchens. This modular approach preserves valuable interior square footage, making it an ideal thermal solution for compact homes, high-rise apartments, and space-constrained engineering projects where every square meter impacts the bottom line.
Beyond spatial efficiency, the physical separation of the compressor from the indoor living space drastically minimizes auditory disturbances. Residents experience a whisper-quiet indoor environment, completely free from the mechanical hum typical of traditional all-in-one heating units. The exterior casing features a weather-resistant, smooth finish that feels solid to the touch and easily withstands harsh outdoor elements, ensuring long-term aesthetic and functional integrity even in demanding climates.

Modern thermal management requires intuitive accessibility. This system features sophisticated mobile application integration, allowing users to remotely orchestrate their climate control with a few taps on a screen. Property owners can schedule heating cycles hours before returning, ensuring a steaming, comfortable shower is ready the moment they arrive. The digital interface provides instantaneous feedback, displaying precise water temperatures and available volume in real time. For larger-scale implementations, the control architecture supports RS485 and Modbus protocols, allowing facility managers to integrate multiple units directly into centralized Building Management Systems (BMS) for streamlined oversight and energy optimization.
Engineered to meet rigorous international performance standards, this thermal solution combines premium materials with advanced thermodynamic engineering to deliver consistent, safe, and highly efficient results for any plumbing infrastructure.
The fundamental split design ensures complete physical separation between the water circulation pathways and the electrical components. This structural isolation eliminates the risk of electrical leakage into the water supply, providing absolute peace of mind for installers, property developers, and end-users alike.
Achieving a Coefficient of Performance (COP) exceeding 4.0, this unit significantly reduces energy consumption compared to conventional all-in-one alternatives. By utilizing internationally recognized, premium-grade compressors and highly conductive heat exchangers, the system maximizes thermal transfer while minimizing electrical draw. The integration of eco-friendly R32 or R290 low-GWP refrigerants further aligns the unit with stringent global environmental directives, enhancing the sustainability profile and market value of the final property development.
Contractors benefit from standardized DN25mm pipe fittings and a logical, modular layout. The reduced indoor footprint simplifies the physical placement of the tank, while the accessible outdoor unit allows technicians to perform routine maintenance without tracking dirt through or disrupting the occupants' indoor activities. This translates directly to lower labor costs and faster project turnaround times.
The system consistently delivers a maximum water temperature of 55℃, providing a steady, reliable stream of hot water even during peak usage hours. Backed by mainstream global market access certifications including CE, CB, and ErP, this equipment meets the strict regulatory requirements necessary for seamless international procurement and large-scale deployment.
Review the exact performance metrics, electrical requirements, and physical dimensions of the KFXRS series below. These parameters have been rigorously validated to ensure precise compatibility with your mechanical, electrical, and plumbing (MEP) requirements.
| Model | KFXRS-7.0I | KFXRS-9.0I |
| Voltage/frequency | 220V/50HZ | 220V/50HZ |
| Heating capacity | 7KW | 9KW |
| Rated input power | 1.8KW | 2.3KW |
| Hot water output | 160L/hour | 200L/hour |
| Hot water temperature | 55℃ | 55℃ |
| Inlet/outlet pipe size | DN25mm | DN25mm |
| Dimension | 1000x300x620mm | 1000x300x620mm |
| Weight | 58KG | 65KG |
| Operation ambient temperature | -7~45℃ | -7~45℃ |
Success in commercial and multi-residential developments hinges on equipment reliability and adaptable deployment. This split heat pump water heater is specifically tailored to address the unique challenges of space-restricted environments while maintaining industrial-grade durability.

The architectural flexibility of the split system makes it the preferred choice for economic hotels, dormitory complexes, and high-density apartment buildings. In hospitality settings, consistent water temperature directly impacts guest satisfaction. By relocating the noise-generating components outdoors, property developers can maximize the acoustic comfort of the living spaces. The ability to integrate these units into a centralized control network allows facility operators to monitor energy usage, adjust temperature setpoints, and preemptively address maintenance needs across hundreds of rooms simultaneously, significantly reducing operational overhead.
Before any unit is approved for dispatch, it undergoes a battery of severe stress tests to ensure longevity. The external chassis is subjected to accelerated salt-spray corrosion testing to verify its resilience in coastal or highly humid climates. Internally, the compressor and refrigerant loops must pass extreme high-pressure evaluations and continuous operation trials in ambient temperatures ranging from a freezing -7℃ up to a blistering 45℃. This uncompromising approach to quality control guarantees a remarkably low failure rate in the field, protecting the reputation of engineering contractors and ensuring uninterrupted service for the final user.